| 3100 and 3200 Series Specifications |
Electrical Output Voltage
Excitation | 0 to 5 VDC, 1 to 5 VDC, 0.5 to 4.5 VDC, 1 to 6 VDC, 0 to 10 VDC
2 VDC Above Span to 30 VDC @ 4.5 mA |
| Electrical Output Ratiometric | 0.5 V to 4.5 V @ 5 VDC ±10% Supply |
| Electrical Output Current Supply Voltage (Vs) | 4 to 20 mA 10 to 30 VDC (24 VDC max. above 110°C applications) |
Accuracy (RSS Method) | ±0.25% Full Scale |
| Type of Pressure | Gauge, Sealed Gauge, Compound |
| Pressure Ranges | 0 to 75, ,100,150, 200, 300, 500, 600, 750, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 5000, 7500.10,000, 15,000, 20,000, 25,000, 30,000, 32,000 psig 10, 16, 25, 40, 60, 100, 160, 250, 400, 600, 1000, 1600, 2200 bar |
Thermal Effects Accuracy specified over full compensated temperature range. | Compensated Range °F (°C): -40 to +250 (-40 to +125) Zero/Span %FS/100°F (100°C) 1.0 (1.5) |
| Media | Gases or liquids compatible with 17-4PH (diaphragm) and 304 (pressure fittings) stainless steel. Note: Hydrogen not recommended for use with 17-4PH stainless steel. |
| Voltage Unit w/ Temperature Output Option Applies to the following: 1 to 5 VDC, 0.5 to 4.5 VDC, and 0.5 to 4.5 Ratiometric output units and limited to connections that have 4 pins. | Model 3100 Temperature Range: Model 3101: Range: -40癈 to +125癈 Model 3102: Range -0癈 to 100癈 Model 3103: Range -0癈 to 80癈 Model 3200 Temperature Range: Model 3201: Range: -40癈 to +125癈 Model 3202: Range -0癈 to 100癈 Model 3203: Range -0癈 to 80癈 |
3200 Heavy Duty Pressure Transducer |
Max Over-Pressure Protection 3 x Full Scale | 0 to 75, 100,150, 200, 300, 500, 600, 750, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 5000, 7500.10,000 psi |
Max Over-Pressure Protection 2.5 x Full Scale | Ranges up to 14,500 psi |
Max Over-Pressure Protection 1.7 x Full Scale | Ranges up to 26,000 psi |